Yaskawa · A1000Fault Code oHWarning
Yaskawa A1000 — oH Heatsink Overtemperature
Raised when the heatsink temperature reaches the pre-alarm level. Fan, airflow or ambient temperature is the cause.
Updated: 2026-07-05
Symptoms
- oH after long operation
- Frequent in hot cabinets
- Fan weak/stopped
Probable Causes
- Fan faulty/dusty
- Air duct blockage
- High ambient temperature
Checkpoints
- Verify fan and airflow
- Clean the heatsink
- Measure ambient temperature
Solution
The fan is replaced; if a temperature-sensor (thermistor) fault is suspected, the board is tested.
Related Products
Related Faults
Facing the same issue?
Send your faulty board to our lab or consult our expert team. Free pre-analysis.