Yaskawa A1000 — oH Heatsink Overtemperature

Raised when the heatsink temperature reaches the pre-alarm level. Fan, airflow or ambient temperature is the cause.

Updated: 2026-07-05

Symptoms

  • oH after long operation
  • Frequent in hot cabinets
  • Fan weak/stopped

Probable Causes

  • Fan faulty/dusty
  • Air duct blockage
  • High ambient temperature

Checkpoints

  • Verify fan and airflow
  • Clean the heatsink
  • Measure ambient temperature

Solution

The fan is replaced; if a temperature-sensor (thermistor) fault is suspected, the board is tested.