ABB ACS580 — 3130 Input Phase Loss

Raised when the drive detects loss or severe imbalance on one of the input (mains) phases. DC-link ripple increases.

Updated: 2026-07-05

Symptoms

  • 3130 trip under load
  • Oscillation/ripple in DC-link voltage
  • Increased drive noise/vibration

Probable Causes

  • One input fuse blown
  • Loose or oxidized mains terminal
  • Mains phase imbalance
  • Input contactor contact problem

Checkpoints

  • Measure the voltage of all three input phases (L1-L2-L3)
  • Check the input fuses
  • Check terminal tightness and oxidation
  • Inspect input contactor contacts

Solution

If 3130 recurs with healthy mains, inspect the input rectifier stage or the DC-link capacitors.